<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15975</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: System air pressure fell below threshold required for Separators during operation
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Measure the air supply volume and pressure. For TS VLF AL use tool
92-0373A
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check incomming air supply pressure while the machine is operating.
Watch it for a complete job cycle.
</text></DescriptionText>
<DescriptionText><text>
Check that the filters are clean.
</text></DescriptionText>
</OperatorAction>
<Cause>
The following 8 errors are for sub systems that use air.
Each error is reported if the system air pressure is below
that required for that specific air user system. The pressure
is measured at the Main pressure sensor. The pressure
is compared to a hard coded minimum threshold at which the device
will operate reliably, at the time when the device is turned on
and when it is turned off.
</Cause>
<Cause>
The most common actual cause is inadequate air supply to the machine
either caused by other machines on the air system or supply hoses that
are too thin or too long.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:26 2008 PST
</Updated>
<Links>
</Links>
</Error>